Principle
High frequency microwave pulses travels along the detecting component steel rope or rod and reflects when veaching the product surface. The time from emission to reception is proportional to the distance between the surface and the reference plane on the instrument.
Features
AVI-GW0X equipped with the advanced microprocessor and unique EchoDiscovery echo processing technology can be used in severe ambience.
AVI-GW0X with extremely low emission power can be mounted on various metal or nonmetal vessels, harmless towards the environment and human beings.
There are multiple options available in choosing various process connection and detecting component, which enables AVI-GW0X to be applied in a broad extent of applications, such as high temperature, high pressure, medium with small dielectric constant and etc.
2 Product Overview
AVI-GW01 AVI-GW02 AVI-GW03

Application: Level measurement for Level measurement for Level measurement for liquids,
liquids/solids, in severe liquids/solids, in severe especially for ones with small
ambience ambience dielectric constant, in severe
ambience
Max. Measurement
Range: Rope:30m/Rod:6m 6m 6m
Measurement Accuracy: ±10mm ±10mm ±10mm
Process Connection: G1½A G2A 1½NPT PTFE flange G1½A G2A
Detection Component
Material: Stainless Steel PTFE PTFE Stainless Steel /PTFE
Process Pressure: -0.1~4MPa -0.1~1.6MPa -0.1~4MPa
Process Temperature: -40~150℃ -40~150℃ -40~150℃
Signal Output: (4~20)mA /HART (4~20)mA /HART (4~20)mA /HART
Power: 2-Wire (DC24V) 2-Wire (DC24V) 2-Wire (DC24V)
4-Wire (DC24V/AC220) 4-Wire (DC24V/AC220) 4-Wire (DC24V/AC220)
AVI-GW04 AVI-GW05 AVI-GW06

Application: Level measurement for Level measurement for Level measurement for
liquids in severe liquids,especially in severe liquids,especially in severe liquids with small
ambience with high ambience with very high dielectric constant or
temperature/pressure temperature and pressure powder
Max. Measurement
Range: Rope:30m/Rod:6m Rope:30m/Rod:6m Rope:30m/Rod:6m
Measurement Accuracy: ±10mm ±10mm ±10mm
Process Connection: G1½A G2A 1½NPT G1½A/G2A/1½NPT G1½A/G2A/1½NPT
Detection Component
Material: Stainless Steel 316L/Chinaware Stainless Steel Chinaware Stainless Steel /PTFE
Process Pressure: -0.1~4MPa Vacuum~40MPa -0.1~4MPa
Process Temperature: -40~200℃ -200~400℃ -40~150℃
Signal Output: (4~20)mA /HART (4~20)mA /HART (4~20)mA /HART
Power: 2-Wire (DC24V) 2-Wire (DC24V) 2-Wire (DC24V)
4-Wire (DC24V/AC220) 4-Wire (DC24V/AC220) 4-Wire (DC24V/AC220)
3 Mounting Requirement
Basic Requirement
Keep in mind that the rope rod is kept away from obstructions within vessel. The obstructions are like ladders, limit switches heating spirals struts and etc Furthermore rope or rods must not intersect the filling streams.
Be cautious during the installation: the level of the measured medium must not be in the blanking zone the mounting location must keep a min distance to the vessel wall the rope or rod is perpendicular to the surface of the measured medium. Local or federal safety instruction must be abided when installation is in explosion hazardous area Aluminium housing is used for intrinsically safe version, which can be used in explosion hazardous areas. The instrument must be connected to ground potential in this situation.
Il lustrations

The reference plane is the thread or flange surface
1 Blanking Zone (Menu 1.10)
2 Length (Menu1 9)
3 Max. Measurement Range (Menu1.2)
4 Min. Measurement Range (Menu 1.1)
5 reference plane
Note: The level of the measured medium must not be in either blanking zone.

The best mounting location for a conical vessel with flat top is the center of the vessel s top, as the effective measurement can reach the bottom of vessel.
Socket
Container Extension

Avoid installation with socket if possible, otherwise try to minimize the length of socket . In case of long socket, small vessel or medium with low dielectric constant you are advised to use AVI-GW06.
Rights and Wrongs in Mounting

1 Wrong: The rod/rope is in/above filling stream, which results in the measurement of filling stream not the target medium.
2 Correct Note: Sun shield or rain-proof is required for outdoor mounting.
Damp-proof

When mounting outdoors humid indoors or on cooling/heating vessels, in order to avoid damp seal rings used on cables should be screwed tight, and the cable must be bended downward outside cable entry, as indicated on the diagram below:
4 Dimension (Unit mm)

Housing 1、2、4 Material PBT AL/316L

Housing 3/5 Two-chamber Material AL/316L
AVI-GW01 AVI-GW02

AVI-GW03 AVI-GW04

AVI-GW05 AVI-GW06

5 Selection & Ordering Information
AVI-GW01
Explosion Proof Approval
1 Standard (without approval)
2 Intrinsically Safe (Exia ⅡC T6)
3 Intrinsically Safe+Explosion proof (Exia ⅡC T6)
Type of detecting component/Material
1 Rope/ 6mm/Stainless Steel316L/PTFE
2 Rope/ 10mm/Stainless Steel316L/PTFE
3 Lengthen PP Rope Stainless Steel 316L
4 Lengthen PP Rod Stainless Steel 316L
5 Lengthen PTFE Rope Stainless Steel 316L
6 Lengthen PTFE Rod Stainless Steel 316L
Z Special Design
Seal/Process Temperature
1 G1½A
2 G2A
3 1½NPT
Z Special Design
Seal/Process Temperature
1 Viton/ (-30~150)℃
2 Kalrez /(-40~150)℃
Electronic
1 (4~20)mA /HART 2-Wire
2 (4~20)mA /(22.8~26.4)V DC/HART 4-Wire
3 (198~242)V AC/HART 4-Wire
4 (4~20)mA /(22.8~26.4)V DC/HART 2-Wire
Z Special Design
Housing/Protection
1 Plastic IP66
2 Aluminium IP67
3 Aluminium (2-chamber) IP67
4 Stainless Steel316L IP67
5 Stainless Steel316L(2-chamber) IP67
Cable Entry
1 M20x1 5
2 ½NPT
Display/Programming
1 No
2 Yes
Rope/rod length
5 digit number(unit:mm)
AVI-GW02
Explosion Proof Approval
1 Standard (without approval)
2 Intrinsically Safe (Exia ⅡC T6)
3 Intrinsically Safe+Explosion proof (Exia ⅡC T6)
Type of detecting component/Material
1 Rod/Φ6mm/ Stainless Steel 316L
Process Connection/Material
1 DN50 PN1 6 Stainless Steel 316L
2 DN80 PN1 6 Stainless Steel 316L
3 DN100 PN1 6 Stainless Steel 316L
4 DN150 PN1 6 Stainless Steel 316L
Z Special Design
Seal/Process Temperature
1 (-40~150)℃
Electronic
1 (4~20)mA /HART 2-Wire
2 (4~20)mA /(22.8~26.4)V DC/HART 4-Wire
3 (198~242)V AC/HART 4-Wire
4 (4~20)mA /(22.8~26.4)V DC/HART 2-Wire
Z Special Design
Housing/Protection
1 Plastic IP66
2 Aluminium IP67
3 Aluminium (2-chamber) IP67
4 Stainless Steel316L IP67
5 Stainless Steel316L(2-chamber) IP67
Cable Entry
1 M20x1 5
2 ½NPT
Display/Programming
1 No
2 Yes
Rope/rod length
5 digit number(unit:mm)
AVI-GW03
Explosion Proof Approval
1 Standard (without approval)
2 Intrinsically Safe (Exia ⅡC T6)
3 Intrinsically Safe+Explosion proof (Exia ⅡC T6)
Type of detecting component/Material
1 Cosx/Stainless Steel 316L
Process Connection/Material
1 Thread G1½A
2 Thread G2A
3 Thread 1½NPT
Z Special Design
Seal/Process Temperature
1 Viton /(-30~150)℃
2 Kalrez /(-40~150)℃
Electronic
1 (4~20)mA /HART 2-Wire
2 (4~20)mA /(22.8~26.4)V DC/HART 4-Wire
3 (198~242)V AC/HART 4-Wire
4 (4~20)mA /(22.8~26.4)V DC/HART 2-Wire
Z Special Design
Housing/Protection
1 Plastic IP66
2 Aluminium IP67
3 Aluminium (2-chamber) IP67
4 Stainless Steel316L IP67
5 Stainless Steel316L(2-chamber) IP67
Cable Entry
1 M20x1 5
2 ½NPT
Display/Programming
1 No
2 Yes
Rope/rod length
5 digit number(unit:mm)
AVI-GW04
Explosion Proof Approval
1 Standard (without approval)
2 Intrinsically Safe (Exia ⅡC T6)
3 Intrinsically Safe+Explosion proof (Exia ⅡC T6)
Type of detecting /Material/Process Temperature
1 Rope Stainless Steel 316L/PTFE
2 Rod Stainless Steel 316L/PTFE
3 Lengthen PP Rope Stainless Steel 316L
4 Lengthen PP Rod Stainless Steel 316L
5 Lengthen PTFE Rope Stainless Steel 316L
6 Lengthen PTFE Rod Stainless Steel 316L
Z Special Design
Process Connection/Material
1 Thread G1½A
2 Thread G2A
3 Thread 1½NPT
Z Special Design
Seal/Process Temperature
1 Viton /(-30~150)℃
2 Kalrez /(-40~150)℃
Electronic
1 (4~20)mA /HART 2-Wire
2 (4~20)mA /(22.8~26.4)V DC/HART 4-Wire
3 (198~242)V AC/HART 4-Wire
4 (4~20)mA /(22.8~26.4)V DC/HART 2-Wire
Z Special Design
Housing/Protection
1 Plastic IP66
2 Aluminium IP67
3 Aluminium (2-chamber) IP67
4 Stainless Steel316L IP67
5 Stainless Steel316L(2-chamber) IP67
Cable Entry
1 M20x1 5
2 ½NPT
Display/Programming
1 No
2 Yes
Rope/rod length
5 digit number(unit:mm)
AVI-GW05
Explosion Proof Approval
1 Standard (without approval)
2 Intrinsically Safe (Exia ⅡC T6)
3 Intrinsically Safe+Explosion proof (Exia ⅡC T6)
Type of detecting component/Material
1 Rope Stainless Steel316L/Ceramic
2 Rod Stainless Steel316L/Ceramic
Process Connection/Material
1 Thread G1½A
2 Thread G2A
3 Thread 1½NPT
Z Special Design
Electronic
1 (4~20)mA /HART 2-Wire
2 (4~20)mA /(22.8~26.4)V DC/HART 4-Wire
3 (198~242)V AC/HART 4-Wire
4 (4~20)mA /(22.8~26.4)V DC/HART 2-Wire
Z Special Design
Housing/Protection
1 Plastic IP66
2 Aluminium IP67
3 Aluminium (2-chamber) IP67
4 Stainless Steel316L IP67
5 Stainless Steel316L(2-chamber) IP67
Cable Entry
1 M20x1 5
2 ½NPT
Display/Programming
1 No
2 Yes
Rope/rod length
5 digit number(unit:mm)
AVI-GW06
Explosion Proof Approval
1 Standard (without approval)
2 Intrinsically Safe (Exia ⅡC T6)
3 Intrinsically Safe+Explosion proof (Exia ⅡC T6)
Type of detecting component/Material
1 Rope Stainless Steel 316L PTFE
2 Rod Stainless Steel 316L PTFE
Process Connection/Material
1 Thread G1½A
2 Thread G2A
3 Thread 1½NPT
Z Special Design
Electronic
1 (4~20)mA /HART 2-Wire
2 (4~20)mA /(22.8~26.4)V DC/HART 4-Wire
3 (198~242)V AC/HART 4-Wire
4 (4~20)mA /(22.8~26.4)V DC/HART 2-Wire
Z Special Design
Housing/Protection
1 Plastic IP66
2 Aluminium IP67
3 Aluminium (2-chamber) IP67
4 Stainless Steel316L IP67
5 Stainless Steel316L(2-chamber) IP67
Process Temperature
1 (-200~400)℃/(Vacuum~4)MPa
2 (-200~400)℃/(Vacuum~40)MPa
Cable Entry
1 M20x1 5
2 ½NPT
Display/Programming
1 No
2 Yes
Rope/rod length
5 digit number(unit:mm)